Abstract

Verification of the Quantitative Determination Method for Phenylephrine Hydrochloride in Solution for Injections

Author(s): A. V. Kryvanych, N. Y. Bevz and V. A. Georgiyants

The spectrophotometric method for quantitative determination of phenylephrine hydrochloride solution for injections has been verified. The method was tested on model mixtures and a batch sample of the drug. The method proposed was verified by the following parameters: specificity, linearity, precision (convergence), accuracy, robustness, the range of application. These metrological characteristics do not exceed the acceptance criteria according to the SPhU. Based on these results the method can be correctly reproduced and is suitable for use in pharmaceutical analysis of injectable medicines containing phenylephrine hydrochloride.